92/38, No.12 Street, Quarter 18, Binh Hung Hoa Ward, Binh Tan District, Ho Chi Minh City, Vietnam.

Vortex Flow Meter

VFM60N Standard Digita vortex flowmeter

Price: Contact

  • Model: VFM60N
  • VFM60 is a powerful flow meter utilizing “Karman vortex” theory, designed to accurately measure the flow rate of various fluids including gas, steam, and liquid. It caters effectively to industries such as chemical processing, power generation, oil and gas, and HVAC systems.

  • Origin: China
  • VFM60N Standard Digita vortex flowmeter

    VFM60 is a powerful flow meter utilizing “Karman vortex” theory, designed to accurately measure the flow rate of various fluids including gas, steam, and liquid. It caters effectively to industries such as chemical processing, power generation, oil and gas, and HVAC systems.

    The product employs advanced VFM60 transmitter technology, which boasts excellent signal processing capabilities, elevating vortex metering technology to new heights. This results in a lower measuring limit, enhanced stability, and superior accuracy. The unique dual-sensor design combined with a specialized signal processing method ensures excellent anti-vibration performance by eliminating interference from vibration signals, thereby offering more reliable operation and an even lower measurement limit.

    VFM60N Standard Digita vortex flowmeter
    VFM60N Standard Digita vortex flowmeter

    Features 

    Features of VFM60N Standard Digita vortex flowmeter

    • Extremely high sensitivity, minimum flow rate down to 2m/s
    • 1:35 super wide turndown ratio
    • Unique dual sensor technology excellent in anti-vibration
    • No moving parts, very small pressure loss
    • Calculate the density and mass flow without any separate sensor
    • Density compensation function available, do not need flow computer for mass flow Password protecting function and self-diagnose function

    Anti-vibration

    VFM60 vortex flow meter have a patent dual-sensor design and is using our latest VPA60 transmitter, which enable it to detect and eliminate vibration signal, and provide with best anti-vibration performance.

    Anti-vibration
    Anti-vibration

     

    Bluetooth operating

    • Parameter & Function setting via Comate bluetooth app
    • Setting auto crosschecking on PHM system
    • Flow signal & data analysis
    • Remote diagnosis
    Bluetooth operating
    Bluetooth operating

    Specification

    Measurement range of VFM60N Digita vortex flowmeter

    Medium Min velocity Max velocity
    Gas 6m/s for DN15, DN20 60m/s (196.9 ft/s)
    (19.7 ft/s) for 0.5″ and 0.75″
    4m/s, DN25、DN32
    (13.1 ft/s) for 1″ and 1.25″
    2m/s, DN40 ~ DN300
    (6.7 ft/s) for 1.5″ ~ 1.2″
    Steam 6m/s for DN15, DN20 70m/s (229.7 ft/s)
    (19.7 ft/s) for 0.5″ and 0.75″
    4m/s, DN25、DN32
    (13.1 ft/s) for 1″ and 1.25″
    2m/s, DN40 ~ DN300
    (6.7 ft/s) for 1.5″ ~ 1.2″
    Liquid 0.3m/s (1 ft/s) 7m/s (23 ft/s)

    Specification of VFM60N series digital vortex flow meter

    End connection Flange DN15~DN300 or 0.5 inch to 12 inch
    Wafer DN15~DN300 or 0.5 inch to 12 inch
    Medium temperature Standard -40 ~ 150 ℃ or -40 ~ 302 ℉
    Medium -40 ~ 250 ℃ or -40 ~ 482 ℉
    High -40 ~ 350 ℃ or -40 ~ 662 ℉
    Power supply 4~20mA 2 wise system 13.5 ~ 42V
    VFM60MV with 4~20mA (2 wire ) 15.5 ~ 42V
    Modbus RTU Current Iq < 9mA 13.4 ~ 42V
    Reynolds and accuracy Gas/steam (m³/h) ±1%RD(Re ≥ 20000)
    ±2%RD(10000 < Re < 20000)
    Liquid (m³/h) ±0.75%RD(Re ≥ 20000)
    ±2%RD(10000 < Re < 20000)
    Gas/steam (m³/h) ±1.5%RD(Re ≥ 20000)
    ±2.5%RD(10000 < Re < 20000)
    Turndown ratio Gas 1:30
    Steam 1:35
    Liquid 1:22
    Repeatability Volume flow ±0.3%
    Mass flow ±0.3%
    Temperature ±0.05 ℃
    Pressure ±0.05%FS
    Upstream/Downstream requires 15 x D / 5 x D
    Details please check
    Viscosity allowance DN15 or 0.5 inch ≤ 4mPas
    DN25 or 1 inch ≤ 5mPas
    DN40~DN300 or 1.5~12 inch ≤ 7mPas
    Anti-vibration (both punch and fixed freq) 0.5g
    Display LCD displayer
    Saturated /superheated steam measurement Support
    HART
    Natural gas/Biogas, ect HART(V5、V7)/ Modbus-RTU/ Pulse
    Communication HART(V5、V7)/ Modbus-RTU/ Pulse
    Explosive proof NEPSI Ex d II c T3 Gb

     

    Model Selection

    1 General model VFM60-MV Vortex mass flowmeter with  integral RTD and pressure sensor Standard
    VFM60-N Vortex flowmeter without integral RTD and pressure sensor Option
    2 Fluid type 1 Liquid Option
    2 Gas Standard
    3 Steam Option
    3 Process connection IN Insertion (only for DN300~ DN1000 or 12 inch~ 40 inch ) Option
    WC Wafer with carbon steel flanges up to 16 barG (232 psiG) (DN15~DN300) Standard
    WF Wafer with stainless steel flanges up to 16 barG (232 psiG) (DN15~DN300) Option
    D1 Flanged DIN PN16 up to 16 barG (232 psiG) (DN15~DN300) Option
    D2 Flanged DIN PN25 up to 25 barG (362 psiG) (DN15~DN300) Option
    D3 Flanged DIN PN40 up to 40 barG (580 psiG) (DN15~DN300) Option
    D4 Flanged DIN PN63 up to 63 barG (913 psiG) (DN15~DN300) Option
    C1 Flanged ANSI CL150 up to 16 barG (232 psiG) (0.5 inch~12 inch) Option
    C2 Flanged ANSI CL300 up to 40 barG (580 psiG) (0.5 inch~12 inch) Option
    C3 Flanged ANSI CL400 up to 63 barG (913 psiG) (0.5 inch~12 inch) Option
    J1 JIS 10K up to 16 barG (232 psiG) (DN15~DN300) Option
    J2 JIS 20K up to 40 barG (580 psiG) (DN15~DN300) Option
    J3 JIS 30K up to 63 barG (913 psiG) (DN15~DN300) Option
    4 Wetted part material 1 OCr18Ni9(304) Standard
    2 316 Option
    Q Other Option
    5 Degreased N Wet part not degreased Standard
    D Wet part degreased for Oxygen measurement Option
    6 Medium Temperature N T≤150℃ Standard
    S T≤250℃(wafer or flanged) Option
    H T≤350℃ (wafer or flanged) Option
    7 Transmitter ML1 Integral transmitter , multi-variable ,bluetooth, RS485, pulse, Standard
    ML2 Integral transmitter , multi-variable ,bluetooth, pulse, 4 wire 4~20mA Option
    ML3 Integral transmitter , multi-variable ,bluetooth, RS485, pulse, 4 wire 4~20mA Option
    ML4 Integral transmitter , multi-variable ,bluetooth, pulse, 4 wire HART@4~20mA Option
    ML5 Integral transmitter , multi-variable , pulse, 2 wire 4~20mA Option
    ML6 Integral transmitter , multi-variable , pulse, 2 wire  HART@4~20mA Option
    MR1 Remote transmitter (dual display) , multi-variable ,bluetooth, RS485, pulse, Option
    MR2 Remote transmitter (dual display) , multi-variable ,bluetooth, RS485, pulse, 4 wire 4~20mA Option
    NL1 Integral transmitter , bluetooth, RS485, pulse, Option
    NL3 Integral transmitter , bluetooth, RS485, pulse, 4 wire 4~20mA Option
    NL4 Integral transmitter , bluetooth, pulse, 4 wire HART@4~20mA Option
    NL6 Integral transmitter ,  pulse, 2 wire  HART@4~20mA Option
    NR1 Remote transmitter (dual display) , bluetooth, RS485, pulse, Option
    NR2 Remote transmitter (single display) , bluetooth, pulse, 4 wire 4~20mA Option
    NR3 Remote transmitter (dual display) , bluetooth, RS485, pulse, 4 wire 4~20mA Option
    NR4 Remote transmitter (single display) , bluetooth, pulse, 4 wire HART@4~20mA Option
    NR6 Remote transmitter (single display) ,  pulse, 2 wire  HART@4~20mA Option
    8 Cable grinder M M20x1.5 Standard
    N NPT 1/2 Option
    9 Ex-proof N No Ex-proof Standard
    1 NEPSI Ex d IIC T3 Gb Option
    10 Pipe size 015 DN15 or 0.5 inch  
    020 DN20 or 0.75 inch  
    025 DN25 or 1 inch  
    032 DN32 or 1.25 inch  
    040 DN40 or 15 inch  
    050 DN50 or 2 inch  
    065 DN65 or 2.5 inch  
    080 DN80 or 3 inch  
    100 DN100 or 4 inch  
    125 DN125 or 5 inch  
    150 DN150 or 6 inch  
    200 DN200 or 8 inch  
    250 DN250 or 10 inch  
    300 DN300 or 12 inch  

     

    Document

    VFM60 series datasheet

    Category
    Online support
  • Consulting - Quotation
    Consulting - Quotation
  • Consulting-Technical
    Consulting-Technical
  • Consulting - Quotation
    Consulting - Quotation
  • Consulting - Technical
    Consulting - Technical
  • Consulting - Quotation
    Consulting - Quotation